China ANSI 52-9 Suspension Cap and Pin Type Porcelain Ceramic Insulator Supplier - Factory Direct Quality for Power Transmission
Drawing
Product Specifications
| Suspension Type Anti-Pollution Insulator for High Voltage (ANSI) | ||||||||||
| Class ANSI | 52-1 | 52-2 | 52-3 | 52-4 | 52-5 | 52-6 | 52-9 | 52-10 | ||
| Main Dimensions (mm) | Diameter | 165 | 190.5 | 254 | 254 | 254 | 254 | 114 | 279.4 | |
| Height | 139.7 | 146 | 146 | 146 | 146 | 146 | 160 | 165 | ||
| Creepage Distance (mm) | 178 | 210 | 292 | 292 | 279 | 279 | 171 | 279 | ||
| Average Flashover Voltage | Power-frequency | Dry (kV) | 60 | 65 | 80 | 80 | 80 | 80 | 80 | 80 |
| Wet (kV) | 30 | 35 | 50 | 50 | 50 | 50 | 30 | 50 | ||
| Critical-Impulse 1.2x50μs Wave | Positive (kV) | 100 | 115 | 125 | 125 | 125 | 125 | 90 | 125 | |
| Negative (kV) | 100 | 115 | 130 | 130 | 130 | 130 | 100 | 130 | ||
| Radio-Influence-Voltage Data | Test Voltage to Ground (kV) | 7.5 | 7.5 | 10 | 10 | 10 | 10 | 7.5 | 10 | |
| Maximum RIV at 1000kHz (μV) | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||
| Electro-mechanical Failing Load (kN) | 45 | 70 | 70 | 70 | 111 | 111 | 45 | 160 | ||
| Power-Frequency Puncture Voltage (kV) | 80 | 90 | 110 | 110 | 110 | 110 | 80 | 110 | ||
| Mechanical Impact Strength (n.m) | 5 | 6 | 6 | 6 | 7 | 7 | 5 | 10 | ||
| Time Load Test Value (kn) | 27 | 44 | 44 | 44 | 67 | 67 | 27 | 107 | ||
Certificate
Packaging
Frequently Asked Questions
What is the standard for these suspension type insulators?
These insulators are designed and manufactured according to the ANSI (American National Standards Institute) standards, specifically covering classes 52-1 through 52-10 for high voltage applications.
What is the maximum creepage distance available?
The creepage distance varies by model, with the ANSI 52-3 and 52-4 classes offering a high creepage distance of up to 292mm, providing excellent performance in polluted environments.
What is the mechanical strength rating of the ANSI 52-10 model?
The ANSI 52-10 model features an Electro-mechanical Failing Load of 160kN and a Time Load Test Value of 107kN, making it suitable for heavy-duty structural requirements.
How do these insulators perform under wet conditions?
The power-frequency wet flashover voltage ranges from 30kV to 50kV depending on the specific ANSI class, ensuring reliable operation during rain or high humidity.
Are these insulators suitable for high-pollution areas?
Yes, these are specifically designed as Anti-Pollution Insulators, featuring optimized profiles and creepage distances to prevent flashover in contaminated environments.
What is the Radio Influence Voltage (RIV) performance?
All listed models maintain a maximum RIV of 50μV at 1000kHz when tested at their respective ground voltages (7.5kV or 10kV), minimizing interference with communication signals.